From 8f6b56b71ccee4eb800a5b1aa1edbbfb0a0cb6b4 Mon Sep 17 00:00:00 2001 From: Jonathan McCrohan Date: Sun, 26 Feb 2012 01:53:38 +0000 Subject: Update 02-fix-wavemonrc.5-man-errors.patch Add fix for hyphen-used-as-minus-sign linitan warning. --- debian/patches/02-fix-wavemonrc.5-man-errors.patch | 37 ++++++++++++++-------- 1 file changed, 23 insertions(+), 14 deletions(-) (limited to 'debian') diff --git a/debian/patches/02-fix-wavemonrc.5-man-errors.patch b/debian/patches/02-fix-wavemonrc.5-man-errors.patch index 16ad534..5870446 100644 --- a/debian/patches/02-fix-wavemonrc.5-man-errors.patch +++ b/debian/patches/02-fix-wavemonrc.5-man-errors.patch @@ -2,11 +2,13 @@ From: Jonathan McCrohan Date: Tue, 21 Feb 2012 22:05:32 +0000 Subject: Fix wavemonrc.5 man errors -Fixes upstream commit 45abbfeecccd90c8c83c38e642c147473a90c40a which causes +a) Fixes upstream commit 45abbfeecccd90c8c83c38e642c147473a90c40a which causes man compilation errors. +b) Fixes lintian hyphen-used-as-minus-sign warning. + diff --git a/wavemonrc.5 b/wavemonrc.5 -index 67dea89..2d8a6ca 100644 +index 67dea89..4a6dd97 100644 --- a/wavemonrc.5 +++ b/wavemonrc.5 @@ -10,7 +10,7 @@ on-screen name is shown in parentheses. @@ -72,25 +74,29 @@ index 67dea89..2d8a6ca 100644 .RS Override the auto-scaling of the bar graphs and histogram, allowing you to set your own scales. .P -@@ -73,7 +73,7 @@ Override the auto-scaling of the bar graphs and histogram, allowing you to set y +@@ -73,24 +73,24 @@ Override the auto-scaling of the bar graphs and histogram, allowing you to set y .B min_signal_level, max_signal_level = .RS .RE -.R (Minimum signal level, Maximum signal level) +(Minimum signal level, Maximum signal level) .RS - Set the left and right boundaries of the signal level scales. Ranges: -128..-60dBm (minimum) and -59..120dBm (maximum). +-Set the left and right boundaries of the signal level scales. Ranges: -128..-60dBm (minimum) and -59..120dBm (maximum). ++Set the left and right boundaries of the signal level scales. Ranges: \-128..\-60dBm (minimum) and \-59..120dBm (maximum). .P -@@ -81,7 +81,7 @@ Set the left and right boundaries of the signal level scales. Ranges: -128..-60d + .RE .B min_noise_level, max_noise_level = .RS .RE -.R (Minimum noise level, Maximum noise level) +(Minimum noise level, Maximum noise level) .RS - These work similar to the signal boundary settings. Ranges: -128..-60dBm - (minimum) and -60..120dBm (maximum). -@@ -90,7 +90,7 @@ These work similar to the signal boundary settings. Ranges: -128..-60dBm +-These work similar to the signal boundary settings. Ranges: -128..-60dBm +-(minimum) and -60..120dBm (maximum). ++These work similar to the signal boundary settings. Ranges: \-128..\-60dBm ++(minimum) and \-60..120dBm (maximum). + .P + .RE .B random = (on|off) .RS .RE @@ -108,7 +114,7 @@ index 67dea89..2d8a6ca 100644 .RS Issue a warning at a given threshold at the lower end of the signal scale. It is meant for alarming you when a signal appears at the receiver. -@@ -107,7 +107,7 @@ scale. It is meant for alarming you when a signal appears at the receiver. +@@ -107,16 +107,16 @@ scale. It is meant for alarming you when a signal appears at the receiver. .B lo_threshold = .RS .RE @@ -116,8 +122,10 @@ index 67dea89..2d8a6ca 100644 +(Low threshold) .RS Sets the threshold value for the 'Low threshold action'. - Range: -120..-60dBm. -@@ -116,7 +116,7 @@ Range: -120..-60dBm. +-Range: -120..-60dBm. ++Range: \-120..\-60dBm. + .P + .RE .B hi_threshold_action = (disabled|beep|flash|beep+flash) .RS .RE @@ -126,16 +134,17 @@ index 67dea89..2d8a6ca 100644 .RS Analogous to lo_threshold_action, only this time the threshold is at the upper end of the scale and the action is performed when the signal level -@@ -128,7 +128,7 @@ will tell you when you should move closer to the base station. +@@ -128,15 +128,15 @@ will tell you when you should move closer to the base station. .B hi_threshold = .RS .RE -.R (High threshold) +(High threshold) .RS - Sets the threshold for the 'High threshold action'. Range: -59..120dBm. +-Sets the threshold for the 'High threshold action'. Range: -59..120dBm. ++Sets the threshold for the 'High threshold action'. Range: \-59..120dBm. .P -@@ -136,7 +136,7 @@ Sets the threshold for the 'High threshold action'. Range: -59..120dBm. + .RE .B startup_screen = (info|histogram|scan window) .RS .RE -- cgit v1.2.3