aboutsummaryrefslogtreecommitdiffstats
path: root/util/scan/dvb-t/fr-Epinal (unfollow)
AgeCommit message (Expand)AuthorFilesLines
2013-09-03Imported Upstream version 1.1.1+rev1207upstream/1.1.1+rev1207etobi1-0/+25
>85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167
.TH wavemonrc 5 "March 2012" Linux "User Manuals"
.SH NAME
$HOME/.wavemonrc \- wavemon configuration file
.SH DESCRIPTION
\fIwavemonrc\fR is the per-user configuration file for \fBwavemon\fR(1).
This page describes its individual configuration options.  Each corresponds
to a configuration item of the \fIPreferences\fR screen (F7 key), whose
on-screen name is shown in parentheses.
.P
.B interface = <ifname>
.RS
.RE
(Interface)
.RS
Selects the wireless interface to use.
.P
.RE
.B cisco_mac = (on|off)
.RS
.RE
(Cisco-style MAC addresses)
.RS
If enabled, display MAC addresses using lower-case hex digits separated by dots
rather than colons.
.P
.RE
.B sort_order = (channel|essid|signal|open|chan/sig|open/sig)
.RS
.RE
(Scan sort type)
.RS
Determines the ordering used in the scan window: \fIchannel\fR sorts by channel number, \fIessid\fR by
access point name, \fIsignal\fR by signal strength, and \fIopen\fR by openness. The combined variants
\fIchan/sig\fR and \fIopen/sig\fR sort first by channel/openness and then by signal strength.
It also affects the status line at the bottom: normally the most crowded channels are listed,
sorting by \fIchannel\fR in descending order switches to least crowded ones instead.
.P
.RE
.B sort_ascending = (on|off)
.RS
.RE
(Scan sort direction)
.RS
Sets the direction of the \fIsort_order\fR: ascending (on) or descending (off).
.P
.RE
.B stat_updates = <n>
.RS
.RE
(Statistics updates)
.RS
Time interval for polling new statistics (including scan refresh). Range: 10..4000ms.
.P
.RE
.B lhist_slot_size = <n>
.RS
.RE
(Histogram update cycles)
.RS
Number of samples used per each histogram slot. For example, if the stat_updates
interval is 500ms and the histogram slot size is 4, the histogram is moved
one slot further every 2 seconds. Range: 1..64.
.P
.RE
.B meter_smoothness = <n>
.RS
.RE
(Level meter smoothness)
.RS
Determines the responsiveness of level meters, tracking the moving average
rather than following each new sample. The given value specifies the percentage
of the history (the 'inertia') of preceding samples. A value of 0 disables
this option. Range: 0..99%.
.P
.RE
.B info_updates = <n>
.RS
.RE
(Dynamic info updates)
.RS
Sets refresh rate for dynamic device parameters (e.g. bitrate) and the
refresh interval for the Scan window (F3). Range: 1..60s.
.P
.RE
.B override_auto_scale = (on|off)
.RS
.RE
(Override scale autodetect)
.RS
Override the auto-scaling of the bar graphs and histogram, allowing you to set your own scales.
.P
.RE
.B min_signal_level, max_signal_level = <n>
.RS
.RE
(Minimum signal level, Maximum signal level)
.RS
Set the left and right boundaries of the signal level scales. Ranges: \-128..\-60dBm (minimum) and \-59..120dBm (maximum).
.P
.RE
.B min_noise_level, max_noise_level = <n>
.RS
.RE
(Minimum noise level, Maximum noise level)
.RS
These work similar to the signal boundary settings. Ranges: \-128..\-60dBm
(minimum) and \-60..120dBm (maximum).
.P
.RE
.B random = (on|off)
.RS
.RE
(Random signals)
.RS
Switches on a fancy random generator for testing.
.P
.RE
.B lo_threshold_action = (disabled|beep|flash|beep+flash)
.RS
.RE
(Low threshold action)
.RS
Issue a warning  at a given threshold at the lower end of the signal
scale. It is meant for alarming you when a signal appears at the receiver.
.P
.RE
.B lo_threshold = <n>
.RS
.RE
(Low threshold)
.RS
Sets the threshold value for the 'Low threshold action'.
Range: \-120..\-60dBm.
.P
.RE
.B hi_threshold_action = (disabled|beep|flash|beep+flash)
.RS
.RE
(High threshold action)
.RS
Analogous to lo_threshold_action, only this time the threshold is at
the upper end of the scale and the action is performed when the signal level
drops below it. The acoustic signal is also different in order to be easily
distinguishable from the lower one. Correctly adjusted, this little fellow
will tell you when you should move closer to the base station.
.P
.RE
.B hi_threshold = <n>
.RS
.RE
(High threshold)
.RS
Sets the threshold for the 'High threshold action'. Range: \-59..120dBm.
.P
.RE
.B startup_screen = (info|histogram|scan window)
.RS
.RE
(Startup screen)
.RS
Which of the screens appears at program startup.
.SH "AUTHOR"
Written by Jan Morgenstern <jan@jm-music.de>.
.SH "REPORTING BUGS"
Send bug reports and/or suggestions to Gerrit Renker <gerrit@erg.abdn.ac.uk>.
.SH "COPYRIGHT"
This is free software with ABSOLUTELY NO WARRANTY. See file COPYING for details.